CHROMIUM VI INSTRUMENTATION
Chromium VI is an important water quality parameter for drinking water and wastewater treatment applications.
Product code: CPR Series/ CRA Series
Producer: Real Tech
Origin: Canada

Detect events rapidly to take early action and improve process control. Real Tech's real-time Chromium VI monitoring solutions can provide significant cost savings.

Real Tech’s innovative multiple wavelength sensors utilize patent-pending and proprietary technology for superior measurement performance across multiple wavelengths of light using UV LEDs. Many compounds absorb light in the UV-VIS spectrum including chromium VI. Real Tech offers both bypass (CRL series) and probe (CRA series) Chromium VI sensor options to allow the right selection for our clients needs. Multiple path length options are also available to ensure our clients have the detection range that meets their monitoring demands.

FEATURES & BENEFITS

  • Affordable real-time chromium VI monitoring
  • Multiple wavelength sensor uses UV LED technology
  • for superior measurement performance
  • Wastewater to high purity water measurement ranges
  • Operator friendly, low maintenance design
  • Quick and simple optical measurements
  • Reagent free operation

1. REAL CHROMIUM VI SENSOR - CRL SERIES

Parameter(s): Chromium VI

CHARACTERISTIC

TECHNICAL DATA

Path Lengths

1, 2, 4, 8 mm (2000 series)
25, 50, 100, 150 mm (4000 series)

Parameters

Chromium VI

Range

Depends on model selected. Refer to range chart

Accuracy

± 1% full scale

Units

mg/L, ppm

Sampling Time

30 seconds

Calibration

Factory calibrated. Field adjustment of calibration is possible.

Cleaning

In-situ cleaning makes cleaning quick and easy. Automatic chemical cleaning is optional.

Self-Diagnostic

Detection and diagnosis of internal system fault

Alarms

Dry contact terminals allow operator configurable alarms for:
high and low set points, low lamp output, leak detect, system fault, etc.

Humidity Control

Humidity sensor with large regeneratable desiccant system

Wavelengths

Multiple wavelengths

Light Source

UV LED

Flow Rate

300 - 1000 mL/min

Pressure Rating

20 PSI maximum

Fluid Connections

1/4" OD tube push-in fittings

Wetted Materials

Kynar, Polyethylene, Quartz, SS 316L, Viton

Electrical/Comm.

From controller

Ambient Temp.

0 to 45°C (32 to 113°F)

Water Temp.

0 to 90°C (32 to 194°F) at 21°C (69.8°F) Ambient temperature

Enclosure

NEMA 4X, wall mountable

Weight

22 lb (2000 series)
24 lb (4000 series)

Dimensions

17"H x 14.25"W x 7.5"D (2000 series)
15.82”H x 13.82”W x 9.00”D (4000 series)

Warranty

2-year limited warranty (Extended care packages available)

* Technical Specifications are subject to change without notice.

* Water temperature range based on material compatibility only. Contact Real Tech to verify application.

 

2. REAL CHROMIUM VI PROBE - CRA SERIES

Parameter(s): Chromium VI

CHARACTERISTIC

TECHNICAL DATA

Path Length Options

1, 2, 4, 10 mm

Parameters

Chromium VI

Range

Depends on model selected. Refer to range chart

Accuracy

± 1% full scale

Units

mg/L

Sampling Time

10 seconds

Calibration

Factory calibrated. Field adjustment of calibration is possible.

Cleaning

Automatic compressed air or pressurized water cleaning with optional Probe Clean System

Self-Diagnostic

Detection and diagnosis of internal system fault

Alarms

Continuous detection of leaks, lamp output, humidity, temperature and electrical fault

Humidity Control

Humidity sensor with desiccant pack

Wavelength

Multiple wavelengths

Light Source

UV LED

Electrical/Comm.

From controller

Operating Temp.

0 to 45°C (32 to 113°F)

Housing Material

Titanium or stainless steel

Wetted Materials

Titanium, Epoxy, Sapphire, SS 316L, Viton

Weight

4.6 lb

Dimensions

15" H x 2.0" Diameter

Warranty

2-year limited warranty (Extended care packages available)

* Technical Specifications are subject to change without notice.

* Operating (water) temperature absolute maximum 55°C (131°F). Instrument performance reduced when operating outside recommended operating range. Contact Real Tech to verify application.