Products
Detect events rapidly to take early action and improve process control. Real Tech's real-time Chromium VI monitoring solutions can provide significant cost savings.
Real Tech’s innovative multiple wavelength sensors utilize patent-pending and proprietary technology for superior measurement performance across multiple wavelengths of light using UV LEDs. Many compounds absorb light in the UV-VIS spectrum including chromium VI. Real Tech offers both bypass (CRL series) and probe (CRA series) Chromium VI sensor options to allow the right selection for our clients needs. Multiple path length options are also available to ensure our clients have the detection range that meets their monitoring demands.
FEATURES & BENEFITS
- Affordable real-time chromium VI monitoring
- Multiple wavelength sensor uses UV LED technology
- for superior measurement performance
- Wastewater to high purity water measurement ranges
- Operator friendly, low maintenance design
- Quick and simple optical measurements
- Reagent free operation
Parameter(s): Chromium VI
CHARACTERISTIC | TECHNICAL DATA |
Path Lengths | 1, 2, 4, 8 mm (2000 series) |
Parameters | Chromium VI |
Range | Depends on model selected. Refer to range chart |
Accuracy | ± 1% full scale |
Units | mg/L, ppm |
Sampling Time | 30 seconds |
Calibration | Factory calibrated. Field adjustment of calibration is possible. |
Cleaning | In-situ cleaning makes cleaning quick and easy. Automatic chemical cleaning is optional. |
Self-Diagnostic | Detection and diagnosis of internal system fault |
Alarms | Dry contact terminals allow operator configurable alarms for: |
Humidity Control | Humidity sensor with large regeneratable desiccant system |
Wavelengths | Multiple wavelengths |
Light Source | UV LED |
Flow Rate | 300 - 1000 mL/min |
Pressure Rating | 20 PSI maximum |
Fluid Connections | 1/4" OD tube push-in fittings |
Wetted Materials | Kynar, Polyethylene, Quartz, SS 316L, Viton |
Electrical/Comm. | From controller |
Ambient Temp. | 0 to 45°C (32 to 113°F) |
Water Temp. | 0 to 90°C (32 to 194°F) at 21°C (69.8°F) Ambient temperature |
Enclosure | NEMA 4X, wall mountable |
Weight | 22 lb (2000 series) |
Dimensions | 17"H x 14.25"W x 7.5"D (2000 series) |
Warranty | 2-year limited warranty (Extended care packages available) |
* Technical Specifications are subject to change without notice.
* Water temperature range based on material compatibility only. Contact Real Tech to verify application.
2. REAL CHROMIUM VI PROBE - CRA SERIES
Parameter(s): Chromium VI
CHARACTERISTIC | TECHNICAL DATA |
Path Length Options | 1, 2, 4, 10 mm |
Parameters | Chromium VI |
Range | Depends on model selected. Refer to range chart |
Accuracy | ± 1% full scale |
Units | mg/L |
Sampling Time | 10 seconds |
Calibration | Factory calibrated. Field adjustment of calibration is possible. |
Cleaning | Automatic compressed air or pressurized water cleaning with optional Probe Clean System |
Self-Diagnostic | Detection and diagnosis of internal system fault |
Alarms | Continuous detection of leaks, lamp output, humidity, temperature and electrical fault |
Humidity Control | Humidity sensor with desiccant pack |
Wavelength | Multiple wavelengths |
Light Source | UV LED |
Electrical/Comm. | From controller |
Operating Temp. | 0 to 45°C (32 to 113°F) |
Housing Material | Titanium or stainless steel |
Wetted Materials | Titanium, Epoxy, Sapphire, SS 316L, Viton |
Weight | 4.6 lb |
Dimensions | 15" H x 2.0" Diameter |
Warranty | 2-year limited warranty (Extended care packages available) |
* Technical Specifications are subject to change without notice.
* Operating (water) temperature absolute maximum 55°C (131°F). Instrument performance reduced when operating outside recommended operating range. Contact Real Tech to verify application.